8. Remote Control
Power: This button turns on the unit or set the device
to standby mode.
CEC: This button turns on the CEC function of the unit or
set it to bypass mode. Please refer to section 6.1 for
more details.
Input selector: Buttons 1~6 to select the desired input
sources. Buttons 7~8 do not functioning for this model.
9. RS-232 Protocol
9.1 Pin Denitions
Baud Rate: 19200 bps
Data Bit: 8 bits
Parity: None
Stop Bit: 1 bit
Flow Control: None
CR-63
POWERCEC
INPUT
34
12
56
78
Switcher Remote Controller
PIN Assignment PIN Assignment
1 NC 1 NC
2 TxD 2 RxD
3 RxD 3 TxD
4 NC 4 NC
5 GND 5 GND
6 NC 6 NC
7 NC 7 NC
8 NC 8 NC
9 NC 9 NC